Highly reproducible, simple and selective analytical method for extractive UV-visible spectrophotometric determination of ruthenium (III): analysis of catalyst, fissium alloy and sequential separation

TitleHighly reproducible, simple and selective analytical method for extractive UV-visible spectrophotometric determination of ruthenium (III): analysis of catalyst, fissium alloy and sequential separation
Publication TypeJournal Article
Year of Publication2020
AuthorsShaikh, AB, Barache, UB, Khogare, BT, Goswami, R, Kokare, BN, Wadgaonkar, PP, Gaikwad, SH
JournalSpectrochimica Acta Part A-Molecular and Biomolecular Spectroscopy
Volume243
Pagination118814
Date PublishedDEC
Type of ArticleArticle
ISSN1386-1425
KeywordsAlloy samples, FBIMMT, Ruthenium(III), Spectrophotometric determination, Synthetic mixtures
Abstract

An easy and selective method has been developed for the extractive spectrophotometric determination of ruthenium(III) with 4-(4'-flurobenzylideneimino)-3-methyl-5-mercapto-1,2,4-triazole (FBIMMT) as a chelating reagent. The basis of the method is the formation of stable complex of `soft base' FBIMMT with `soft acid' ruthenium(M). The reagent FBIMMT in n-butanol easily forms extractable yellow coloured complex with ruthenium(III) in acetate buffer of pH 4.8. The absorbance of [Ru(III)-FBIMMT] complex is measured at 394 nm against the reagent blank. Good linearity range of concentration up to 27.0 mu g mL(-1) of ruthenium(III) is attained with correlation coefficient R-2 = 0.998. The optimum concentration range is 6 to 27.0 mu g mL(-1) which is deduced by Ringbom's plot. The apparent molar absorptivity found to be 2.75 x 10(3) L mol(-1) cm(-1). Some additional characteristics such as limit of detection (LOD = 0.48 mu g mL(-1)), limit of quantification (LOQ = 1.19 mu g mL(-1)), and Sandell's sensitivity (SS = of 0.0367 mu g cm(-2)) arc also estimated. The composition of [Ru (III)-FBIMMT1 complex has been established from Job's continuous variation method, mole ratio method, and log-log plot method. The specificity towards ruthenium(III) is well studied and appropriate masking agents are applied wherever required to boost it. The intra-day and inter-day precision values are found to be brilliant with % relative standard deviation of 0.52 and 0.68 respectively with % accuracy within the range of 99.00-100. The method is effectively used for determination of ruthenium(III) from water samples, binary and ternary synthetic mixtures, fissium alloy samples and catalyst materials. A scheme for sequential group separation of ruthenium(III), palladium(II) and osmium (VIII) has also been developed. The reproducible results of the present method confirm that the method has a good potential for quantitative determination of ruthenium(III) from various matrices. (C) 2020 Elsevier B.V. All rights reserved.

DOI10.1016/j.saa.2020.118814
Type of Journal (Indian or Foreign)

Foreign

Impact Factor (IF)

3.232

Divison category: 
Polymer Science & Engineering

Add new comment