Off-site emergency scenario, a case study from a LPG bottling plant

TitleOff-site emergency scenario, a case study from a LPG bottling plant
Publication TypeJournal Article
Year of Publication2006
AuthorsRuj, B, Rehman, I, Bandyopadhya, AK
JournalJournal of Loss Prevention in the Process Industries
Volume19
Issue6
Pagination645-647
Date PublishedNOV
Type of ArticleArticle
ISSN0950-4230
KeywordsBLEVE, emergency plan, LPG, off-site
Abstract

After Bhopal disaster, emergency planning in an industrial area has become inevitable. The off-site emergency plan is an integral part of any major hazard control system. Boiling Liquid Expanding Vapour Explosion (BLEVE) leads to fatal consequences. This paper highlights some salient features of the emergency scenario, which ultimately leads to fireball with enormous pressure wave all around. (C) 2006 Elsevier Ltd. All rights reserved.

DOI10.1016/j.jlp.2006.03.003
Type of Journal (Indian or Foreign)

Foreign

Impact Factor (IF)1.409
Divison category: 
Chemical Engineering & Process Development