Specific reagent for Cr(III): imaging cellular uptake of Cr(III) in Hct116 cells and theoretical rationalization

TitleSpecific reagent for Cr(III): imaging cellular uptake of Cr(III) in Hct116 cells and theoretical rationalization
Publication TypeJournal Article
Year of Publication2015
AuthorsAli, F, Saha, S, Maity, A, Taye, N, Si, MKanti, Suresh, E, Ganguly, B, Chattopadhyay, S, Das, A
JournalJournal of Physical Chemistry B
Volume119
Issue41
Pagination13018-13026
Date PublishedOCT
ISSN1520-6106
Abstract

A new rhodamine-based reagent (L-1), trapped inside the micellar structure of biologically benign Triton-X 100, could be used for specific recognition of Cr(III) in aqueous buffer medium having physiological pH. This visible light excitable reagent on selective binding to Cr(III) resulted in a strong fluorescence turn-on response with a maximum at similar to 583 nm and tail of that luminescence band extended until 650 nm, an optical response that is desired for avoiding the cellular autofluorescence. Interference studies confirm that other metal ions do not interfere with the detection process of Cr(III) in aqueous buffer medium having pH 7.2. To examine the nature of binding of Cr(III) to L-1, various spectroscopic studies are performed with the model reagent L-1 which tend to support Cr(III)-eta(2)-olefin pi-interactions involving two olefin bonds in molecular probe L-1. Computational studies are also performed with another model reagent L-M to examine the possibility of such Cr(III)-eta(2)-olefin pi-interactions. Presumably, polar functional groups of the model reagent L-M upon coordination to the Cr(III) center effectively reduce the formal charge on the metal ion and this is further substantiated by results of the theoretical studies. This assembly is found to be cell membrane permeable and shows insignificant toxicity toward live colon cancer cells (Hct116). Confocal laser scanning microscopic studies further revealed that the reagent L-1 could be used as an imaging reagent for detection of cellular uptake of Cr(III) in pure aqueous buffer medium by Hct116 cells. Examples of a specific reagent for paramagnetic Cr(III) with luminescence ON response are scanty in the contemporary literature. This ligand design helped us in achieving the turn on response by utilizing the conversion from spirolactam to an acyclic xanthene form on coordination to Cr(III).

DOI10.1021/acs.jpcb.5b07565
Type of Journal (Indian or Foreign)

Foreign

Impact Factor (IF)3.187
Divison category: 
Organic Chemistry