<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Chekin, Fereshteh</style></author><author><style face="normal" font="default" size="100%">Myshin, Vladyslav</style></author><author><style face="normal" font="default" size="100%">Ye, Ran</style></author><author><style face="normal" font="default" size="100%">Melinte, Sorin</style></author><author><style face="normal" font="default" size="100%">Singh, Santosh K.</style></author><author><style face="normal" font="default" size="100%">Kurungot, Sreekumar</style></author><author><style face="normal" font="default" size="100%">Boukherroub, Rabah</style></author><author><style face="normal" font="default" size="100%">Szunerits, Sabine</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Graphene-modified electrodes for sensing doxorubicin hydrochloride in human plasma</style></title><secondary-title><style face="normal" font="default" size="100%">Analytical and Bioanalytical Chemistry</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Disposable electrodes</style></keyword><keyword><style  face="normal" font="default" size="100%">doxorubicin</style></keyword><keyword><style  face="normal" font="default" size="100%">Nitrogen-doped reduced graphene oxide</style></keyword><keyword><style  face="normal" font="default" size="100%">Serum</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2019</style></year><pub-dates><date><style  face="normal" font="default" size="100%">MAR</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">411</style></volume><pages><style face="normal" font="default" size="100%">1509-1516</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;Doxorubicin (DOX), an anthracycline molecule, is currently one of the most widely used anticancer drugs in clinics. Systematic treatment of patients with DOX is known to be accompanied by several unpleasant side effects due to the toxicity of the drug. Thus, monitoring of DOX concentration in serum samples has become increasingly important to avoid side effects and ensure therapeutic efficiency. In this study, we discuss the construction of a disposable electrochemical sensor for the direct monitoring of DOX in clinical blood samples. The sensor is based on coating a gold electrode in a flexible integrated electrode construct formed on polyimide sheets using photolithography, with nitrogen-doped reduced graphene oxide (N-rGO) suspended in chitosan. Under optimized conditions, a linear relationship between the oxidative peak current and the concentration of DOX in the range of 0.010-15M with a detection limit of 10nM could be achieved. The sensor was adapted to monitor DOX in serum samples of patients under anticancer treatment.&lt;/p&gt;
</style></abstract><issue><style face="normal" font="default" size="100%">8</style></issue><work-type><style face="normal" font="default" size="100%">Article</style></work-type><custom3><style face="normal" font="default" size="100%">&lt;p&gt;Foreign&lt;/p&gt;
</style></custom3><custom4><style face="normal" font="default" size="100%">&lt;p&gt;3.286&lt;/p&gt;
</style></custom4></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Emwas, Abdul-Hamid</style></author><author><style face="normal" font="default" size="100%">Zacharias, Helena U.</style></author><author><style face="normal" font="default" size="100%">Alborghetti, Marcos Rodrigo</style></author><author><style face="normal" font="default" size="100%">Gowda, G. A. Nagana</style></author><author><style face="normal" font="default" size="100%">Raftery, Daniel</style></author><author><style face="normal" font="default" size="100%">Mckay, Ryan T.</style></author><author><style face="normal" font="default" size="100%">Chang, Chung-ke</style></author><author><style face="normal" font="default" size="100%">Saccenti, Edoardo</style></author><author><style face="normal" font="default" size="100%">Gronwald, Wolfram</style></author><author><style face="normal" font="default" size="100%">Schuchardt, Sven</style></author><author><style face="normal" font="default" size="100%">Leiminger, Roland</style></author><author><style face="normal" font="default" size="100%">Merzaban, Jasmeen</style></author><author><style face="normal" font="default" size="100%">Madhoun, Nour Y.</style></author><author><style face="normal" font="default" size="100%">Iqbal, Mazhar</style></author><author><style face="normal" font="default" size="100%">Alsiary, Rawiah A.</style></author><author><style face="normal" font="default" size="100%">Shivapurkar, Rupali</style></author><author><style face="normal" font="default" size="100%">Pain, Arnab</style></author><author><style face="normal" font="default" size="100%">Shanmugam, Dhanasekaran</style></author><author><style face="normal" font="default" size="100%">Ryan, Danielle</style></author><author><style face="normal" font="default" size="100%">Roy, Raja</style></author><author><style face="normal" font="default" size="100%">Schirra, Horst Joachim</style></author><author><style face="normal" font="default" size="100%">Morris, Vanessa</style></author><author><style face="normal" font="default" size="100%">Zeri, Ana Carolina</style></author><author><style face="normal" font="default" size="100%">Alahmari, Fatimah</style></author><author><style face="normal" font="default" size="100%">Kaddurah-Daouk, Rima</style></author><author><style face="normal" font="default" size="100%">Salek, Reza M.</style></author><author><style face="normal" font="default" size="100%">LeVatte, Marcia</style></author><author><style face="normal" font="default" size="100%">Berjanskii, Mark</style></author><author><style face="normal" font="default" size="100%">Lee, Brian</style></author><author><style face="normal" font="default" size="100%">Wishart, David S.</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Recommendations for sample selection, collection and preparation for NMR-based metabolomics studies of blood</style></title><secondary-title><style face="normal" font="default" size="100%">Metabolomics</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Blood</style></keyword><keyword><style  face="normal" font="default" size="100%">Metabolites</style></keyword><keyword><style  face="normal" font="default" size="100%">Metabolomics</style></keyword><keyword><style  face="normal" font="default" size="100%">NMR</style></keyword><keyword><style  face="normal" font="default" size="100%">Plasma</style></keyword><keyword><style  face="normal" font="default" size="100%">Serum</style></keyword><keyword><style  face="normal" font="default" size="100%">Standardization</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2025</style></year><pub-dates><date><style  face="normal" font="default" size="100%">MAY</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">21</style></volume><pages><style face="normal" font="default" size="100%">66</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;
	BackgroundMetabolic profiling of blood metabolites, particularly in plasma and serum, is vital for studying human diseases, human conditions, drug interventions and toxicology. The clinical significance of blood arises from its close ties to all human cells and facile accessibility. However, patient-specific variables such as age, sex, diet, lifestyle and health status, along with pre-analytical conditions (sample handling, storage, etc.), can significantly affect metabolomic measurements in whole blood, plasma, or serum studies. These factors, referred to as confounders, must be mitigated to reveal genuine metabolic changes due to illness or intervention onset.Review objectiveThis review aims to aid metabolomics researchers in collecting reliable, standardized datasets for NMR-based blood (whole/serum/plasma) metabolomics. The goal is to reduce the impact of confounding factors and enhance inter-laboratory comparability, enabling more meaningful outcomes in metabolomics studies.Key conceptsThis review outlines the main factors affecting blood metabolite levels and offers practical suggestions for what to measure and expect, how to mitigate confounding factors, how to properly prepare, handle and store blood, plasma and serum biosamples and how to report data in targeted NMR-based metabolomics studies of blood, plasma and serum.&lt;/p&gt;
</style></abstract><issue><style face="normal" font="default" size="100%">3</style></issue><work-type><style face="normal" font="default" size="100%">Review</style></work-type><custom3><style face="normal" font="default" size="100%">&lt;p&gt;
	Foreign&lt;/p&gt;
</style></custom3><custom4><style face="normal" font="default" size="100%">&lt;p&gt;
	4.1&lt;/p&gt;
</style></custom4></record></records></xml>