<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Ram, Farsa</style></author><author><style face="normal" font="default" size="100%">Gudadhe, Aniket</style></author><author><style face="normal" font="default" size="100%">Vijayakanth, Thangavel</style></author><author><style face="normal" font="default" size="100%">Aherrao, Swapnil</style></author><author><style face="normal" font="default" size="100%">Borkar, Vivek</style></author><author><style face="normal" font="default" size="100%">Boomishankar, Ramamoorthy</style></author><author><style face="normal" font="default" size="100%">Shanmuganathan, Kadhiravan</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Nanocellulose reinforced flexible composite nanogenerators with enhanced vibrational energy harvesting and sensing properties</style></title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Composite</style></keyword><keyword><style  face="normal" font="default" size="100%">Nanofiber</style></keyword><keyword><style  face="normal" font="default" size="100%">piezoelectric</style></keyword><keyword><style  face="normal" font="default" size="100%">pressure</style></keyword><keyword><style  face="normal" font="default" size="100%">Sensor</style></keyword><keyword><style  face="normal" font="default" size="100%">vibration</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2020</style></year><pub-dates><date><style  face="normal" font="default" size="100%">JUL</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">2</style></volume><pages><style face="normal" font="default" size="100%">2550-2562</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;We report here enhanced vibration and pressure sensing properties of nanocellulose reinforced flexible composite piezoelectric nanogenerators (PENGs). Surface fluorinated nanocellulose crystals (FNC) were incorporated into poly(vinylidene fluoride) (PVDF) and electrospun into composite nanofibers. Incorporation of only 2 wt % FNC in PVDF resulted in a significant enhancement in pressure sensitivity with a very low detectable pressure limit of 10 Pa and a sensitivity of up to 18 mV/kPa. The composite PENGs also demonstrated very high sensitivity for forced continuous vibrations. 2FNC/PVDF composites resulted in an order of magnitude higher voltage response over neat PVDF for a given strain. When PENGs were mounted on a vacuum pump for transduction of mechanical vibrations into electrical energy, 2FNC/PVDF composite devices manifested similar to 3.8 times enhanced voltage output over neat PVDF and faster charging of a capacitor. The enhanced piezoelectric properties of PVDF/FNC nanocomposites could be attributed to the tailored interface between PVDF and nanocellulose and enhanced polarizability.&lt;/p&gt;
</style></abstract><issue><style face="normal" font="default" size="100%">7</style></issue><work-type><style face="normal" font="default" size="100%">Article</style></work-type><custom3><style face="normal" font="default" size="100%">&lt;p&gt;Foreign&lt;/p&gt;
</style></custom3><custom4><style face="normal" font="default" size="100%">&lt;p&gt;NA&lt;/p&gt;
</style></custom4></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Agarwal, Harshal</style></author><author><style face="normal" font="default" size="100%">Thosar, Aniket U.</style></author><author><style face="normal" font="default" size="100%">Bhat, Santoshkumar D.</style></author><author><style face="normal" font="default" size="100%">Lele, Ashish K.</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Interdigitated flow field impact on mass transport and electrochemical reaction in high-temperature polymer electrolyte fuel cell</style></title><secondary-title><style face="normal" font="default" size="100%">Journal of Power Sources</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">HT-PEFC</style></keyword><keyword><style  face="normal" font="default" size="100%">Interdigitated flow field</style></keyword><keyword><style  face="normal" font="default" size="100%">Mass transport mechanism</style></keyword><keyword><style  face="normal" font="default" size="100%">pressure</style></keyword><keyword><style  face="normal" font="default" size="100%">stoichiometry</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2022</style></year><pub-dates><date><style  face="normal" font="default" size="100%">JUN </style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">532</style></volume><pages><style face="normal" font="default" size="100%">231319</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;
	The enhanced performance of Polybenzimidazole (PBI) based high-temperature polymer electrolyte fuel cell (HT-PEFC) with interdigitated flow field over the other flow fields can be a consequence of higher average pressure developed on the flow field due to dead end in the channels or faster mass transport due to pressuredriven convection in the gas diffusion layer (GDL). In the present study, the effect of average pressure on the flow field and mass transport mechanism in the GDL on the HT-PEFC performance have been systematically decoupled. Three-dimensional simulation validated by experimental studies confirm that the enhanced performance in case of the interdigitated flow field is due to faster mass transport in the GDL and not due to higher average gas pressure. The simulation studies are performed on the interdigitated flow field and compared against the parallel flow field to have an insight into the effect of key operating and geometric parameters. There exists an optimum value for channel to rib ratio and current density saturates after an air stoichiometry of 4 which is validated by experiments.&lt;/p&gt;
</style></abstract><work-type><style face="normal" font="default" size="100%">Article</style></work-type><custom3><style face="normal" font="default" size="100%">&lt;p&gt;
	Foreign&lt;/p&gt;
</style></custom3><custom4><style face="normal" font="default" size="100%">&lt;p&gt;
	9.794&lt;/p&gt;
</style></custom4></record></records></xml>