<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Kale, Anup</style></author><author><style face="normal" font="default" size="100%">Kale, Sonia</style></author><author><style face="normal" font="default" size="100%">Yadav, Prasad</style></author><author><style face="normal" font="default" size="100%">Gholap, Haribhau</style></author><author><style face="normal" font="default" size="100%">Pasricha, Renu</style></author><author><style face="normal" font="default" size="100%">Jog, Jyoti Prakash</style></author><author><style face="normal" font="default" size="100%">Lefez, Benoit</style></author><author><style face="normal" font="default" size="100%">Hannoyer, Beatrice</style></author><author><style face="normal" font="default" size="100%">Shastry, Padma</style></author><author><style face="normal" font="default" size="100%">Ogale, Satishchandra B.</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Magnetite/CdTe magnetic-fluorescent composite nanosystem for magnetic separation and bio-imaging</style></title><secondary-title><style face="normal" font="default" size="100%">Nanotechnology</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2011</style></year><pub-dates><date><style  face="normal" font="default" size="100%">JUN</style></date></pub-dates></dates><number><style face="normal" font="default" size="100%">22</style></number><publisher><style face="normal" font="default" size="100%">IOP PUBLISHING LTD</style></publisher><pub-location><style face="normal" font="default" size="100%">TEMPLE CIRCUS, TEMPLE WAY, BRISTOL BS1 6BE, ENGLAND</style></pub-location><volume><style face="normal" font="default" size="100%">22</style></volume><pages><style face="normal" font="default" size="100%">Article No. 225101</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;A new synthesis protocol is described to obtain a CdTe decorated magnetite bifunctional nanosystem via dodecylamine (DDA) as cross linker. High resolution transmission electron microscopy (HRTEM), energy-dispersive x-ray spectroscopy (EDAX), vibrating sample magnetometry (VSM), Fourier transform infrared spectroscopy (FTIR), diffuse reflectance spectroscopy (DRS) and fluorescence microscopy are used to characterize the constitution, size, composition and physical properties of these superparamagnetic-fluorescent nanoparticles. These CdTe decorated magnetite nanoparticles were then functionalized with anti-epidermal growth factor receptor (EGFR) antibody to specifically target cells expressing this receptor. The EGFR is a transmembrane glycoprotein and is expressed on tumor cells from different tissue origins including human leukemic cell line Molt-4 cells. The magnetite-CdTe composite nanosystem is shown to perform excellently for specific selection, magnetic separation and fluorescent detection of EGFR positive Molt-4 cells from a mixed population. Flow cytometry and confocal laser scanning microscopy results show that this composite nanosystem has great potential in antibody functionalized magnetic separation and imaging of cells using cell surface receptor antibody.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">22</style></issue><work-type><style face="normal" font="default" size="100%">Article</style></work-type><custom3><style face="normal" font="default" size="100%">Foreign</style></custom3><custom4><style face="normal" font="default" size="100%">4.41</style></custom4></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Morarka, Amit</style></author><author><style face="normal" font="default" size="100%">Agrawal, Shailaja</style></author><author><style face="normal" font="default" size="100%">Kale, Sonia</style></author><author><style face="normal" font="default" size="100%">Kale, Anup</style></author><author><style face="normal" font="default" size="100%">Ogale, Satishchandra B.</style></author><author><style face="normal" font="default" size="100%">Paknikar, Kishore</style></author><author><style face="normal" font="default" size="100%">Bodas, Dhananjay S.</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Quantum dot based immunosensor using 3D circular microchannels fabricated in PDMS</style></title><secondary-title><style face="normal" font="default" size="100%">Biosensors &amp; Bioelectronics</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Capillary driven flows</style></keyword><keyword><style  face="normal" font="default" size="100%">Circular microfluidics</style></keyword><keyword><style  face="normal" font="default" size="100%">Immunosensor</style></keyword><keyword><style  face="normal" font="default" size="100%">QDs</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2011</style></year><pub-dates><date><style  face="normal" font="default" size="100%">FEB</style></date></pub-dates></dates><number><style face="normal" font="default" size="100%">6</style></number><publisher><style face="normal" font="default" size="100%">ELSEVIER ADVANCED TECHNOLOGY</style></publisher><pub-location><style face="normal" font="default" size="100%">OXFORD FULFILLMENT CENTRE THE BOULEVARD, LANGFORD LANE, KIDLINGTON, OXFORD OX5 1GB, OXON, ENGLAND</style></pub-location><volume><style face="normal" font="default" size="100%">26</style></volume><pages><style face="normal" font="default" size="100%">3050-3053</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;Microchannel is basic functional component of microfluidic chip and every step-forward of its construction technique has been receiving concern all over the world. The present work describes a novel, rapid and simple fabrication technique for building 3D microchannels in poly(dimethyl siloxane) (PDMS) elastomer. These microchannels were used for rapid detection of antigens (E. coli) by quantum dot (QD) based approach. Luminescent QD (CdTe) were synthesized by aqueous method and characterized using high resolution transmission electron microscopy (HRTEM), fluorescence spectroscopy and X-ray diffraction (XRD). The QDs were functionalized with anti-E. coli antibodies for immuno-detection. The reported process allowed easier and faster method of fabrication of circular 3D micochannels and demonstrated their potential use in an immuno-biosensor device. (C) 2010 Elsevier B.V. All rights reserved.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">6</style></issue><work-type><style face="normal" font="default" size="100%">Article</style></work-type><custom3><style face="normal" font="default" size="100%">Foreign</style></custom3><custom4><style face="normal" font="default" size="100%">5.96
</style></custom4></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Kale, Sonia</style></author><author><style face="normal" font="default" size="100%">Kale, Anup</style></author><author><style face="normal" font="default" size="100%">Gholap, Haribhau</style></author><author><style face="normal" font="default" size="100%">Rana, Abhimanyu</style></author><author><style face="normal" font="default" size="100%">Desai, Rama</style></author><author><style face="normal" font="default" size="100%">Banpurkar, Arun G.</style></author><author><style face="normal" font="default" size="100%">Ogale, Satishchandra</style></author><author><style face="normal" font="default" size="100%">Shastry, Padma</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Quantum dot bio-conjugate: as a western blot probe for highly sensitive detection of cellular proteins</style></title><secondary-title><style face="normal" font="default" size="100%">Journal of Nanoparticle Research</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Detection</style></keyword><keyword><style  face="normal" font="default" size="100%">Imaging</style></keyword><keyword><style  face="normal" font="default" size="100%">nanomedicine</style></keyword><keyword><style  face="normal" font="default" size="100%">quantum dot</style></keyword><keyword><style  face="normal" font="default" size="100%">Rapid</style></keyword><keyword><style  face="normal" font="default" size="100%">sensors</style></keyword><keyword><style  face="normal" font="default" size="100%">Western blot</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2012</style></year><pub-dates><date><style  face="normal" font="default" size="100%">MAR</style></date></pub-dates></dates><number><style face="normal" font="default" size="100%">3</style></number><publisher><style face="normal" font="default" size="100%">SPRINGER</style></publisher><pub-location><style face="normal" font="default" size="100%">VAN GODEWIJCKSTRAAT 30, 3311 GZ DORDRECHT, NETHERLANDS</style></pub-location><volume><style face="normal" font="default" size="100%">14</style></volume><pages><style face="normal" font="default" size="100%">732</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;In the present study, we report a quantum dot (QD)-tailored western blot analysis for a sensitive, rapid and flexible detection of the nuclear and cytoplasmic proteins. Highly luminescent CdTe and (CdTe) ZnS QDs are synthesized by aqueous method. High resolution transmission electron microscopy, Raman spectroscopy, fourier transform infrared spectroscopy, fluorescence spectroscopy and X-ray diffraction are used to characterize the properties of the quantum dots. The QDs are functionalized with antibodies of prostate apoptosis response-4 (Par-4), poly(ADP-ribose) polymerases and beta actin to specifically bind with the proteins localized in the nucleus and cytoplasm of the cells, respectively. The QD-conjugated antibodies are used to overcome the limitations of conventional western blot technique. The sensitivity and rapidity of protein detection in QD-based approach is very high, with detection limits up to 10 pg of protein. In addition, these labels provide the capability of enhanced identification and localization of marker proteins in intact cells by confocal laser scanning microscopy.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">3</style></issue><custom3><style face="normal" font="default" size="100%">Foreign</style></custom3><custom4><style face="normal" font="default" size="100%">2.175
</style></custom4></record></records></xml>