<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Kulkarni, Amol A.</style></author><author><style face="normal" font="default" size="100%">Ranade, Vivek V.</style></author><author><style face="normal" font="default" size="100%">Rajeev, R.</style></author><author><style face="normal" font="default" size="100%">Koganti, S. B.</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Pressure drop across vortex diodes: experiments and design guidelines</style></title><secondary-title><style face="normal" font="default" size="100%">Chemical Engineering Science</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Aspect ratio</style></keyword><keyword><style  face="normal" font="default" size="100%">Diodicity</style></keyword><keyword><style  face="normal" font="default" size="100%">Nozzles</style></keyword><keyword><style  face="normal" font="default" size="100%">pressure drop</style></keyword><keyword><style  face="normal" font="default" size="100%">Vortex diode</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2009</style></year><pub-dates><date><style  face="normal" font="default" size="100%">MAR</style></date></pub-dates></dates><number><style face="normal" font="default" size="100%">6</style></number><publisher><style face="normal" font="default" size="100%">PERGAMON-ELSEVIER SCIENCE LTD</style></publisher><pub-location><style face="normal" font="default" size="100%">THE BOULEVARD, LANGFORD LANE, KIDLINGTON, OXFORD OX5 1GB, ENGLAND</style></pub-location><volume><style face="normal" font="default" size="100%">64</style></volume><pages><style face="normal" font="default" size="100%">1285-1292</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;Vortex diodes are used as leaky non-return valves in applications where it is desirable to avoid valves with moving parts. Despite their use in practice for several decades, no clear guidelines for design and optimization of vortex diodes are available. Detailed experimental study on flow and pressure drop characteristics of vortex diodes was therefore carried out to evolve such guidelines. The study covered a wide range of vortex diodes. The variation of diodicity (ratio of pressure drop for reverse and forward flow for the same flow rate) with respect to diode geometry, diode size (d(c)), aspect ratio (d(c)/h), nozzle configuration and Reynolds number (Re) was studied. The experimental results were critically analyzed to develop a design methodology. The methodology is shown to be useful for obtaining the diode dimensions that would yield the desired diodicity for the required operating flow rate. (c) 2008 Elsevier Ltd. All rights reserved.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">6</style></issue><custom3><style face="normal" font="default" size="100%">Foreign</style></custom3><custom4><style face="normal" font="default" size="100%">2.379</style></custom4></record><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Suryawanshi, Pravin G.</style></author><author><style face="normal" font="default" size="100%">Bhandari, Vinay M.</style></author><author><style face="normal" font="default" size="100%">Sorokhaibam, Laxmi Gayatri</style></author><author><style face="normal" font="default" size="100%">Ruparelia, Jayesh P.</style></author><author><style face="normal" font="default" size="100%">Ranade, Vivek V.</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Solvent degradation studies using hydrodynamic cavitation</style></title><secondary-title><style face="normal" font="default" size="100%">Environmental Progress &amp; Sustainable Energy</style></secondary-title></titles><keywords><keyword><style  face="normal" font="default" size="100%">Effluent treatment</style></keyword><keyword><style  face="normal" font="default" size="100%">industry</style></keyword><keyword><style  face="normal" font="default" size="100%">pollution</style></keyword><keyword><style  face="normal" font="default" size="100%">Vortex diode</style></keyword><keyword><style  face="normal" font="default" size="100%">wastewater</style></keyword></keywords><dates><year><style  face="normal" font="default" size="100%">2018</style></year><pub-dates><date><style  face="normal" font="default" size="100%">JAN</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">37</style></volume><pages><style face="normal" font="default" size="100%">295-304</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;Hydrodynamic cavitation for the degradation of organic solvents was investigated in detail using a newer form of cavitating device-vortex diode. The results were also compared with that using conventional cavitating device orifice. Removal of three different organic solventsacetone, methyl ethyl ketone (MEK), and toluene were studied on a pilot plant with capacity of 1m(3)/h. The effect of different operating parameters such as inlet pressure, initial concentration, and reactor type on the degradation rate of solvent was investigated in detail. The results revealed that efficiency of solvent removal varies substantially with the change in physical operating conditions and nature of the solvent. It was found that up to 80% degradation could be achieved for toluene (cavitational yield 32.2 x 10(-3) mg/J), substantially higher than that for acetone and MEK indicating the effect of molecular weight/structure in the degradation process. Further, the results clearly indicated chemical oxidation as a predominant mechanism for degradation and not physical destruction. Vortex diode that works on the principle of vortex generation for cavitation, was found to be far superior over conventional cavitating device-orifice- approximate to up to eight times higher cavitational yield could be obtained for toluene as compared to orifice. The results of this study provide newer insight into solvent removal using hydrodynamic cavitation and would have bearing on the treatment of solvent containing wastewaters. (C) 2017 American Institute of Chemical Engineers&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">1</style></issue><work-type><style face="normal" font="default" size="100%">Article</style></work-type><custom3><style face="normal" font="default" size="100%">Foreign</style></custom3><custom4><style face="normal" font="default" size="100%">1.672</style></custom4></record></records></xml>