<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Sudhakaran, Amitha Kalappurakkal</style></author><author><style face="normal" font="default" size="100%">Sreekantan, Sreejith</style></author><author><style face="normal" font="default" size="100%">Marimuthu, Banu</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Reimagining CO2 management: SWOT analysis and global outlook on CCUS and ICCU technologies</style></title><secondary-title><style face="normal" font="default" size="100%">Sustainable Chemistry for Climate Action</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2025</style></year><pub-dates><date><style  face="normal" font="default" size="100%">DEC</style></date></pub-dates></dates><volume><style face="normal" font="default" size="100%">7</style></volume><pages><style face="normal" font="default" size="100%">100139</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;
	&lt;span style=&quot;color: rgb(31, 31, 31); font-family: ElsevierGulliver, Georgia, &amp;quot;Times New Roman&amp;quot;, Times, STIXGeneral, &amp;quot;Cambria Math&amp;quot;, &amp;quot;Lucida Sans Unicode&amp;quot;, &amp;quot;Microsoft Sans Serif&amp;quot;, &amp;quot;Segoe UI Symbol&amp;quot;, &amp;quot;Arial Unicode MS&amp;quot;, serif, sans-serif; font-size: 16px;&quot;&gt;The persistent rise in atmospheric CO&lt;/span&gt;&lt;span style=&quot;box-sizing: border-box; margin: 0px; padding: 0px; line-height: 0; position: relative; vertical-align: baseline; bottom: -0.25em; color: rgb(31, 31, 31); font-family: ElsevierGulliver, Georgia, &amp;quot;Times New Roman&amp;quot;, Times, STIXGeneral, &amp;quot;Cambria Math&amp;quot;, &amp;quot;Lucida Sans Unicode&amp;quot;, &amp;quot;Microsoft Sans Serif&amp;quot;, &amp;quot;Segoe UI Symbol&amp;quot;, &amp;quot;Arial Unicode MS&amp;quot;, serif, sans-serif;&quot;&gt;2&lt;/span&gt;&lt;span style=&quot;color: rgb(31, 31, 31); font-family: ElsevierGulliver, Georgia, &amp;quot;Times New Roman&amp;quot;, Times, STIXGeneral, &amp;quot;Cambria Math&amp;quot;, &amp;quot;Lucida Sans Unicode&amp;quot;, &amp;quot;Microsoft Sans Serif&amp;quot;, &amp;quot;Segoe UI Symbol&amp;quot;, &amp;quot;Arial Unicode MS&amp;quot;, serif, sans-serif; font-size: 16px;&quot;&gt;&amp;nbsp;levels, driven by industrialization and fossil fuel dependence, has made carbon dioxide a central target in global climate mitigation efforts. Despite its thermodynamic stability and linear geometry, which make its activation inherently difficult, CO&lt;/span&gt;&lt;span style=&quot;box-sizing: border-box; margin: 0px; padding: 0px; line-height: 0; position: relative; vertical-align: baseline; bottom: -0.25em; color: rgb(31, 31, 31); font-family: ElsevierGulliver, Georgia, &amp;quot;Times New Roman&amp;quot;, Times, STIXGeneral, &amp;quot;Cambria Math&amp;quot;, &amp;quot;Lucida Sans Unicode&amp;quot;, &amp;quot;Microsoft Sans Serif&amp;quot;, &amp;quot;Segoe UI Symbol&amp;quot;, &amp;quot;Arial Unicode MS&amp;quot;, serif, sans-serif;&quot;&gt;2&lt;/span&gt;&lt;span style=&quot;color: rgb(31, 31, 31); font-family: ElsevierGulliver, Georgia, &amp;quot;Times New Roman&amp;quot;, Times, STIXGeneral, &amp;quot;Cambria Math&amp;quot;, &amp;quot;Lucida Sans Unicode&amp;quot;, &amp;quot;Microsoft Sans Serif&amp;quot;, &amp;quot;Segoe UI Symbol&amp;quot;, &amp;quot;Arial Unicode MS&amp;quot;, serif, sans-serif; font-size: 16px;&quot;&gt;&amp;nbsp;has long been identified as a major greenhouse gas since the mid-20th century. This review presents a comprehensive outlook on Carbon Capture, Utilization, and Storage (CCUS) technologies, with a focused discussion on Integrated Carbon Capture and Utilization (ICCU) approaches. We begin with a brief historical and scientific background on CO&lt;/span&gt;&lt;span style=&quot;box-sizing: border-box; margin: 0px; padding: 0px; line-height: 0; position: relative; vertical-align: baseline; bottom: -0.25em; color: rgb(31, 31, 31); font-family: ElsevierGulliver, Georgia, &amp;quot;Times New Roman&amp;quot;, Times, STIXGeneral, &amp;quot;Cambria Math&amp;quot;, &amp;quot;Lucida Sans Unicode&amp;quot;, &amp;quot;Microsoft Sans Serif&amp;quot;, &amp;quot;Segoe UI Symbol&amp;quot;, &amp;quot;Arial Unicode MS&amp;quot;, serif, sans-serif;&quot;&gt;2&lt;/span&gt;&lt;span style=&quot;color: rgb(31, 31, 31); font-family: ElsevierGulliver, Georgia, &amp;quot;Times New Roman&amp;quot;, Times, STIXGeneral, &amp;quot;Cambria Math&amp;quot;, &amp;quot;Lucida Sans Unicode&amp;quot;, &amp;quot;Microsoft Sans Serif&amp;quot;, &amp;quot;Segoe UI Symbol&amp;quot;, &amp;quot;Arial Unicode MS&amp;quot;, serif, sans-serif; font-size: 16px;&quot;&gt;&amp;nbsp;as a greenhouse gas and the pressing need to curb emissions. A critical evaluation of various capture technologies-post-combustion, pre-combustion, oxy-fuel, and direct air capture is provided, highlighting their principles, merits, and limitations. The current global landscape of CCUS infrastructure, including pilot, commercial, and developing-scale operations, is summarized. A SWOT (Strengths, Weaknesses, Opportunities, and Threats) analysis is presented to assess the viability of CCUS pathways. Particular emphasis is placed on CO&lt;/span&gt;&lt;span style=&quot;box-sizing: border-box; margin: 0px; padding: 0px; line-height: 0; position: relative; vertical-align: baseline; bottom: -0.25em; color: rgb(31, 31, 31); font-family: ElsevierGulliver, Georgia, &amp;quot;Times New Roman&amp;quot;, Times, STIXGeneral, &amp;quot;Cambria Math&amp;quot;, &amp;quot;Lucida Sans Unicode&amp;quot;, &amp;quot;Microsoft Sans Serif&amp;quot;, &amp;quot;Segoe UI Symbol&amp;quot;, &amp;quot;Arial Unicode MS&amp;quot;, serif, sans-serif;&quot;&gt;2&lt;/span&gt;&lt;span style=&quot;color: rgb(31, 31, 31); font-family: ElsevierGulliver, Georgia, &amp;quot;Times New Roman&amp;quot;, Times, STIXGeneral, &amp;quot;Cambria Math&amp;quot;, &amp;quot;Lucida Sans Unicode&amp;quot;, &amp;quot;Microsoft Sans Serif&amp;quot;, &amp;quot;Segoe UI Symbol&amp;quot;, &amp;quot;Arial Unicode MS&amp;quot;, serif, sans-serif; font-size: 16px;&quot;&gt;&amp;nbsp;capture mechanisms via absorption (liquid solvents like amines, amino acids, ILs, ammonia, and alkaline solutions) and adsorption (solid sorbents), followed by a detailed literature survey of solvent-based capture methods. Recognizing the isolated inefficiencies of standalone capture or utilization processes, the review underscores the emerging importance of ICCU strategies. Recent advancements in CO&lt;/span&gt;&lt;span style=&quot;box-sizing: border-box; margin: 0px; padding: 0px; line-height: 0; position: relative; vertical-align: baseline; bottom: -0.25em; color: rgb(31, 31, 31); font-family: ElsevierGulliver, Georgia, &amp;quot;Times New Roman&amp;quot;, Times, STIXGeneral, &amp;quot;Cambria Math&amp;quot;, &amp;quot;Lucida Sans Unicode&amp;quot;, &amp;quot;Microsoft Sans Serif&amp;quot;, &amp;quot;Segoe UI Symbol&amp;quot;, &amp;quot;Arial Unicode MS&amp;quot;, serif, sans-serif;&quot;&gt;2&lt;/span&gt;&lt;span style=&quot;color: rgb(31, 31, 31); font-family: ElsevierGulliver, Georgia, &amp;quot;Times New Roman&amp;quot;, Times, STIXGeneral, &amp;quot;Cambria Math&amp;quot;, &amp;quot;Lucida Sans Unicode&amp;quot;, &amp;quot;Microsoft Sans Serif&amp;quot;, &amp;quot;Segoe UI Symbol&amp;quot;, &amp;quot;Arial Unicode MS&amp;quot;, serif, sans-serif; font-size: 16px;&quot;&gt;&amp;nbsp;conversion to methanol, methane, and formic acid via integrated systems are discussed, highlighting the synergy between capture and conversion units.&lt;/span&gt;&lt;/p&gt;
</style></abstract><work-type><style face="normal" font="default" size="100%">Article</style></work-type><custom3><style face="normal" font="default" size="100%">&lt;p&gt;
	Foreign&lt;/p&gt;
</style></custom3><custom4><style face="normal" font="default" size="100%">&lt;p&gt;
	5.4&lt;/p&gt;
</style></custom4></record></records></xml>