<?xml version="1.0" encoding="UTF-8"?><xml><records><record><source-app name="Biblio" version="7.x">Drupal-Biblio</source-app><ref-type>17</ref-type><contributors><authors><author><style face="normal" font="default" size="100%">Mane, Sachin</style></author><author><style face="normal" font="default" size="100%">Ponrathnam, Surendra</style></author><author><style face="normal" font="default" size="100%">Chavan, Nayaku</style></author></authors></contributors><titles><title><style face="normal" font="default" size="100%">Role of interfacial tension of solvating diluents and hydrophilic-hydrophobic cross-linkers in hyper-cross-linked solid supports</style></title><secondary-title><style face="normal" font="default" size="100%">Industrial &amp; Engineering Chemistry Research</style></secondary-title></titles><dates><year><style  face="normal" font="default" size="100%">2015</style></year><pub-dates><date><style  face="normal" font="default" size="100%">JUL</style></date></pub-dates></dates><number><style face="normal" font="default" size="100%">27</style></number><publisher><style face="normal" font="default" size="100%">AMER CHEMICAL SOC</style></publisher><pub-location><style face="normal" font="default" size="100%">1155 16TH ST, NW, WASHINGTON, DC 20036 USA</style></pub-location><volume><style face="normal" font="default" size="100%">54</style></volume><pages><style face="normal" font="default" size="100%">6893-6901</style></pages><language><style face="normal" font="default" size="100%">eng</style></language><abstract><style face="normal" font="default" size="100%">&lt;p&gt;The properties of a hyper-cross-linked solid support are the outcome Of the interfacial tension created by solvating/nonsolvating diluents, the hydrophilicity/hydrophobicity of the cross-linkers, and their concentrations. Interestingly, a More hydrophobic diluent and cross-linker as well as a higher concentration of cross-linker-containing copolymer revealed an increase In surface area. A high surface area and low cross-link density (CLD) polymer illustrated higher epoxy content. Importantly, maximum surface area (533 m(2)/g) Was obtained at high CLD; inversely, epoxy,content (1.83 mmol/g) was higher at low CLD polymer. Notably, greater rigidity of cross-linker and its higher concentration increased T-max and T-g; contrarily, greater flexibility of cross-linker and its concentration attenuated T-max and T-g. Thermal study demonstrated the thermostability (300 degrees C) and polymer safe temperature (220 degrees C). Indeed, a lower solubility parameter difference between polymer and swelling solvent produces a higher polymer-solvent interaction parameter, resulting in increased polymer swelling. Polymers with high surface area and low CLD demonstrated greater swelling behavior.&lt;/p&gt;</style></abstract><issue><style face="normal" font="default" size="100%">27</style></issue><custom3><style face="normal" font="default" size="100%">&lt;p&gt;Foreign&lt;/p&gt;</style></custom3><custom4><style face="normal" font="default" size="100%">2.567</style></custom4></record></records></xml>